- This topic has 2 replies, 2 voices, and was last updated July 17, 2017 by Adam S.
VPG boot order delay not working in failover test
The forum ‘VMware’ is closed to new topics and replies.
Hi we are just getting started with our implementation of zerto and are running 5.0 update 3 with VMware 6u3 on the backend. I’ve created a VPG which contains 4 vms. On the boot order config screen I’v broken these into two groups (2 vms per group) with a boot delay of 300 seconds on the second group. However when I run a failover test they all boot at exactly the same time and the delay seems to have no effect. Thoughts or ideas? Thanks
Thanks. It looks like that’s the key. I kept thinking the delay listed beside a group was the delay before that group fired. Didn’t even occur to me that the delay was after the group but before the next.
The forum ‘VMware’ is closed to new topics and replies.